Validation: Bow-Shock Stand-Off of a Cylinder and a Sphere

Supersonic bluff bodies: bow-shock stand-off at Mach 1.5-3 (documented over-prediction)

Status: open discrepancy, resolution-limited. Code: master at 0cdfdf02a. Example: examples/2D_ibm_cylinder_standoff. Last run: 2026-11-22.

Purpose

The distance of the detached bow shock from a bluff body is a sensitive check of an immersed boundary in supersonic flow: the shock stands only a few cells from the wall at the resolutions a 3D run can afford. This measures the stand-off of a sphere at Mach 1.5, 2 and 3 and of a cylinder at Mach 2, against Billig's correlation Billig [7] and against an independent body-fitted solution, and shows how the error falls with the grid.

Setup

Item Value
Geometry sphere (patch_ib geometry 8) or cylinder (geometry 2), D = 1, centred on a cell-centre row of the stagnation line
Flow ideal gas, \(\gamma\) = 1.4, sound speed 1, Mach 1.5, 2, 3, impulsive start from the free stream, inviscid
Grid sphere 20, 30, 40 and 60 cells/D at Mach 2, 20 and 40 at Mach 1.5 and 3; domain [-1.5 D, 2.5 D] x [-2 D, 2 D] in each lateral direction; cylinder 20, 40 and 80 cells/D, [-2.5 D, 2.5 D] x [-2 D, 2 D]
Boundaries extrapolation on every face
Wall fixed, no slip (inviscid flow, so the wall acts as a slip wall for the normal flux), inverse-distance image points
Numerics WENO5-M, HLLC, SSP-RK3, acoustic CFL 0.4, fixed step
Length t u/R = 40 (sphere), 60 (cylinder), 8 and 12 saves
Hardware NVIDIA A100 80GB (Georgia Tech), NVHPC 25.11, double precision (sphere); GNU 13 CPU (cylinder and body-fitted solver)

Reference data

  • Billig [Billig1967:] \(\Delta/R = 0.143\exp(3.24/M^2)\) (sphere), \(0.386\exp(4.67/M^2)\) (cylinder). An inviscid, high-Reynolds-number fit; the paper's equation number was not re-read.
  • The normal-shock pressure ratio of the Rankine-Hugoniot jump (p2/p1 = 4.5 at Mach 2) and the Rayleigh pitot pressure (1.253 p2 at Mach 2) for the nose-pressure check.
  • Body-fitted reference: examples/2D_ibm_cylinder_standoff/bodyfitted_sphere.py, an axisymmetric Euler solver on a polar mesh around the sphere (finite volumes weighted by the cylindrical radius, MUSCL-minmod, HLLC on the rotated face normal, SSP-RK3; no immersed boundary). Outer radius 2.2 R, 80 and 160 cells in each direction; steady to 1e-5 R over the last 8 R/u at Mach 2.

Quantities

  • Stand-off \(\Delta/R\): the distance from the body surface to the first point, scanning inward on the stagnation line from the inflow, where the pressure reaches the mean of p1 and the normal-shock p2; linear interpolation between cells. Mean of the last three saves; the range over them is listed.
  • p_nose/p2: the pressure of the last cell before the body over p2 (theory: the pitot ratio, 1.253 at Mach 2, 1.388 at Mach 1.5, 1.167 at Mach 3).
  • Script: examples/2D_ibm_cylinder_standoff/standoff.py.

Results

Sphere, A100:

M cells/D Delta/R range over the last three saves Billig error vs Billig error vs body-fitted
1.5 20 0.6988 0.001 0.6036 +15.8 % +14.0 %
1.5 40 0.6650 0.002 0.6036 +10.2 % +8.5 %
2 20 0.4167 0.008 0.3215 +29.6 % +19.1 %
2 30 0.4025 0.003 0.3215 +25.2 % +15.1 %
2 40 0.3939 0.008 0.3215 +22.5 % +12.6 %
2 60 0.3776 0.0005 0.3215 +17.5 % +7.9 %
3 20 0.2482 0.036 0.2050 +21.1 % +13.9 %
3 40 0.2469 0.007 0.2050 +20.4 % +13.3 %

Body-fitted solver ( \(\Delta/R\) on 80 and 160 cells): Mach 1.5 0.6130 and 0.6131 (1.6 % above Billig); Mach 2 0.3489 and 0.3498 (Billig 8.1 % low of the body-fitted value); Mach 3 0.2153 and 0.2179 (Billig 5.9 % low; changing by 1.2 % between the grids).

The nose pressure at Mach 2 is 1.15-1.26 p2 against the pitot value 1.253 (it oscillates with the shock position); at Mach 1.5, 1.29-1.41 against 1.388.

Assessment

  • The stand-off error against Billig falls with the grid at Mach 1.5 (+15.8 to +10.2 %) and 2 (+29.6, +25.2, +22.5 %), as in the earlier measurements of this configuration (+27.5, +22.0 and +17.5 % at 20, 40 and 60 cells/D in a viscous Re 5000 run; the 60 cells/D value agrees).
  • Against the body-fitted solution the error at Mach 2 is +19.1, +15.1, +12.6 and +7.9 % at 20, 30, 40 and 60 cells/D, falling at an observed order of about 0.6 (20 to 40 cells/D) and 1.1 (40 to 60). Billig's correlation is 8.1 % low at Mach 2 against the converged body-fitted value, so errors quoted against it overstate the immersed boundary's by about that much.
  • The sphere is resolution-limited, not a defect of the measurement: the stand-off is 4-12 cells at these grids and three definitions of the shock position agree in the earlier runs.
  • Status is an open discrepancy: no grid here is in the asymptotic range, and Mach 3 is unsettled.

Known limitations

  • Mach 3 is unsteady. The stand-off oscillates between saves by 0.007 R (40 cells/D) to 0.036 R (20 cells/D) and the nose pressure is 1.04-1.20 p2 against 1.167. The body-fitted solver at Mach 3 shows a stand-off that still changes by 1.2 % between 80 and 160 cells. Whether the MFC oscillation is a carbuncle of the HLLC solver was not tested (an earlier Python prototype showed one, steady with HLL); no sensor-switched Riemann solver is proposed here.
  • Cylinder. The stand-off of the cylinder does not settle in 60 R/u: Mach 2 at 20 cells/D 1.414 R (+14.0 % against Billig's 1.241 R, range 0.016), at 40 cells/D 1.464 R and still rising (1.425, 1.458, 1.508 over the last three saves), at 80 cells/D 1.377 R (+11.0 %, 1.354, 1.368, 1.408 over the last three saves, still rising). At Mach 1.5 (40 cells/D, domain from -3.5 D) it is still moving toward the inflow at the end (3.19 to 3.37 R over the last saves, Billig 3.08 R), and at Mach 3 it is 0.771 R (+18.9 %, range 0.026). The cylinder numbers are not a validation; the CI-sized case is a regression test.
  • Viscous runs (Re 5000) were not repeated; in earlier runs the 2D stand-off changed by under 0.5 % between inviscid and Re 5000.
  • First-order no-slip wall (the ghost velocity is the wall value, #2389): it biases the stand-off the other way from the discrepancy; not quantified here.
  • Run only to t u/R = 40, which settles the sphere at Mach 1.5 and 2 (60 cells/D: 0.3776 R in each of the last five saves to 0.0005); the Mach 2 sequence is not extrapolated.
  • The body-fitted solver is axisymmetric inviscid Euler with an outer boundary at 2.2 R; at Mach 2 a 3 R boundary changed it by 0.0008 R in earlier runs.

Reproduce

./mfc.sh run examples/2D_ibm_cylinder_standoff/case.py -t pre_process simulation -n 1 --gpu -- \
--dim 3 --cells_per_D 40 --steps 0 --tstar 40 --frames 8
python3 examples/2D_ibm_cylinder_standoff/standoff.py <run directory>
python3 examples/2D_ibm_cylinder_standoff/bodyfitted_sphere.py --mach 2 --nr 160 --nphi 160

--mach 1.5 and --mach 3 for the other rows, --dim 2 --xu 2.5 --steps 0 --tstar 60 for the cylinder (a build without MPI adds --serial_io). The suite runs the CI-sized cylinder as 2D -> IBM -> Bow Shock Standoff.

Page last updated: 2026-11-23