Slip immersed walls: mass conservation, curvature pressure and the CCST ghost state
Status: partially validated (mass budget and exact vortex); open discrepancy for slip walls in unsteady shock flow and close approach. Code: master at 0cdfdf02a. Example: examples/2D_ibm_slip_cylinder. Last run: 2026-11-23.
Purpose
Gas at tens to hundreds of m/s slides along 50-micron bodies in particle-resolved shock flows, and the slip wall has to conserve the gas mass and give the right pressure on a curved surface. This checks three things of the slip-wall ghost state of an immersed boundary against exact results: the gas mass in a closed box (with and without ib_mass_relax), the near-wall pressure and velocity of an exact steady vortex (the curvature term of the ghost pressure, the image-point interpolation ib_ip_interp and ib_slip_ccst, the curvature-corrected symmetry technique of Dadone and Grossman [19]), and records two cases of slip walls that do not work.
Setup
| Item | Value |
| Geometry | fixed circle R = 50 um (patch_ib(1)%geometry = 2, patch_ib(1)%slip = T, patch_ib(1)%moving_ibm = 0), centred in a square box |
| Gas | inviscid, gamma = 1.4, stagnation state 1e5 Pa and 1.2 kg/m^3 |
| Mass budget | uniform flow at Mach 0.5; box of side 16 R, fully periodic; one flow-through; 16 and 32 cells per R |
| Vortex | \(u_\theta = M c_0 R/r\) with M = 0.3 and 0.6 at the wall, isentropic density and pressure; box of side 6 R, extrapolation boundaries; run time \(0.4\,(3R)/c_0\) before waves from the boundaries return; 10, 20 and 40 cells per R |
| Numerics | WENO5 (mapped, mp_weno), HLLC, SSP-RK3, adaptive CFL 0.5, fd_order = 2 |
| Options set | ib_mass_relax 0, 1 or 30 (mass budget); ib_ip_interp 1 or 2 and ib_slip_ccst F or T (vortex); the curvature term of the ghost pressure is always on |
| Hardware | GNU 13, CPU, one rank, double precision |
Reference data
- Mass. In a periodic box with no source the total gas mass is constant.
- Exact vortex. \(u_\theta = M c_0 R/r\), \(T/T_0 = 1 - \frac{\gamma-1}{2}(u_\theta/c_0)^2\), \(\rho = \rho_0 (T/T_0)^{1/(\gamma-1)}\), \(p = p_0 (T/T_0)^{\gamma/(\gamma-1)}\). An exact steady Euler solution tangent to the wall, with \(dp/dr = \rho u_\theta^2/r\) (the balance the curvature term of the ghost pressure imposes).
Quantities
- Mass change. The sum of the density over the fluid cells (centres outside the body) at the saves, relative to the first save (check_slip.py).
- Vortex error. Root-mean-square over the cells of a wall-distance band (in cells) of \((p-p_\mathrm{ex})/(\frac12\rho_0 (M c_0)^2)\), \((u_\theta-u_{\theta,\mathrm{ex}})/(M c_0)\) and \(u_r/(M c_0)\) (zero in the exact solution), at the end of the run. Only the first band (0 to 1 cells) is tabulated.
Results
Gas mass in a closed box, one flow-through (changes at half and at the end of the flow-through):
| cells per R | ib_mass_relax | half a flow-through | one flow-through |
| 16 | 0 (what -1 gives for a fixed body) | +1.69e-3 | +3.61e-3 |
| 16 | 30 | +4.3e-5 | +5.8e-5 |
| 16 | 1 | -5.2e-14 | -1.2e-13 |
| 32 | 0 | +1.00e-3 | +2.08e-3 |
| 32 | 1 | -1.0e-13 | -2.3e-13 |
Exact vortex, M = 0.3 at the wall, first-band rms error at 10 / 20 / 40 cells per R (observed orders 10 to 20, 20 to 40):
| Scheme | Pressure | Order | Tangential velocity | Order | Radial velocity | Order |
| default image point | 3.28e-02 / 1.58e-02 / 6.38e-03 | 1.1, 1.3 | 3.19e-02 / 2.00e-02 / 1.07e-02 | 0.7, 0.9 | 1.31e-02 / 6.73e-03 / 2.61e-03 | 1.0, 1.4 |
| TSC (ib_ip_interp = 2) | 1.23e-02 / 4.53e-03 / 1.97e-03 | 1.4, 1.2 | 3.26e-02 / 2.25e-02 / 1.39e-02 | 0.5, 0.7 | 2.92e-03 / 1.29e-03 / 5.37e-04 | 1.2, 1.3 |
| ib_slip_ccst, default image point | 5.96e-02 / 3.56e-02 / 1.23e-02 | 0.7, 1.5 | 2.68e-02 / 1.84e-02 / 1.04e-02 | 0.5, 0.8 | 1.94e-02 / 1.23e-02 / 4.39e-03 | 0.7, 1.5 |
| ib_slip_ccst, TSC | 4.51e-03 / 1.22e-03 / 2.40e-04 | 1.9, 2.3 | 1.13e-03 / 7.27e-04 / 2.49e-04 | 0.6, 1.5 | 1.64e-03 / 5.38e-04 / 1.29e-04 | 1.6, 2.1 |
Exact vortex, M = 0.6:
| Scheme | Pressure | Order | Tangential velocity | Order | Radial velocity | Order |
| default image point | 2.57e-02 / 1.43e-02 / 5.11e-03 | 0.8, 1.5 | 3.37e-02 / 1.97e-02 / 9.95e-03 | 0.8, 1.0 | 1.92e-02 / 9.45e-03 / 3.74e-03 | 1.0, 1.3 |
| TSC (ib_ip_interp = 2) | 6.49e-03 / 2.74e-03 / 1.20e-03 | 1.2, 1.2 | 3.59e-02 / 2.50e-02 / 1.54e-02 | 0.5, 0.7 | 2.21e-03 / 1.11e-03 / 3.62e-04 | 1.0, 1.6 |
| ib_slip_ccst, default image point | 4.16e-02 / 2.09e-02 / 8.09e-03 | 1.0, 1.4 | 2.23e-02 / 1.44e-02 / 8.80e-03 | 0.6, 0.7 | 2.46e-02 / 1.44e-02 / 5.41e-03 | 0.8, 1.4 |
| ib_slip_ccst, TSC | 5.04e-03 / 1.37e-03 / 3.17e-04 | 1.9, 2.1 | 1.70e-03 / 7.58e-04 / 2.74e-04 | 1.2, 1.5 | 2.91e-03 / 8.46e-04 / 2.21e-04 | 1.8, 1.9 |
Assessment
- With the default ib_mass_relax a fixed slip wall gains gas: 0.36 % of the box mass per flow-through at 16 cells per R. ib_mass_relax = 1 holds the mass to round-off (1e-13), and 30 to 6e-5. The drift falls slowly with resolution (3.6e-3 at 16 cells per R, 2.1e-3 at 32: a factor 1.7 for doubling), so the option is the remedy.
- The near-wall pressure error of the exact vortex falls at first order (1.1 to 1.5) with the default image point and the curvature term, and 1.9 to 2.3 with ib_slip_ccst and TSC weights. TSC alone lowers the pressure error 3 to 4 times at 40 cells per R; with ib_slip_ccst and TSC it is 27 times lower at M = 0.3 and 16 times lower at M = 0.6 than the default.
- The tangential velocity error stays at first order or below (0.5 to 1.0) with the default ghost copy and with TSC alone, and TSC makes it larger (1.4e-2 against 1.1e-2 at 40 cells per R, M = 0.3); only ib_slip_ccst with TSC removes it (2.5e-4 at 40 cells per R, 43 times lower).
- ib_slip_ccst with the default image point is worse in pressure than the curvature term alone on all three grids; use it with ib_ip_interp = 2.
- The same vortex runs reproduce, to three digits, the first-band errors measured for these options before they were merged (pressure 3.28e-2 / 1.58e-2 / 6.38e-3 at M = 0.3 with the default options), so the merged code matches the study that motivated it.
- Status is partially validated: only a fixed circle, steady inviscid flow and 2D were run; the options were not measured on a moving or accelerating slip body, on a sphere, or in the shock-curtain flow.
Known limitations
- Slip curtains are unsupported. A shock through a 2D curtain of slip cylinders (about 115 um diameter, 16 cells per diameter, area fraction 0.21, Mach 1.66) fails shortly after the shock enters the curtain (two-way coupled moving particles); the same curtain with no-slip walls runs to the end. The likely cause is the inviscid slip model in 2D: the gas stays attached to each cylinder and expands at the shoulders toward vacuum, deeper as the grid is refined, where published inviscid slip-wall bed simulations Mehta et al. [54] are 3D (the flow can relieve sideways) and body fitted. This was not verified in MFC (an independent prototype of the 2D Euler problem keeps a positive minimum pressure, so it does not reproduce the failure itself). Use no-slip walls for curtains.
- Slip particles in close approach. A gap of under about two cells between two slip bodies (or a body and a wall) drains to vacuum (mechanism not isolated).
- Unsteady flow with ib_slip_ccst. Conserving total enthalpy between the image point and the ghost holds only for steady flow. A version of the option failed in three of three runs of a 2D shock curtain of about 40 slip particles (NaN partway through the run) where the zero-gradient slip fill passed four of four; the merged option was not run in that curtain. A nearly stagnant image point is given a bounded tangential speed (0.5 to 2 times the image point's), and the option is refused with chemistry.
- Local conservation. ib_mass_relax returns each body's net ghost-layer intake, so the body's total gas mass is conserved; the face fluxes that carry the intake are not corrected, and the correction is local to two cells of the body. A conservative face flux (cut cells) is not available. Count the mass of all fluid cells: the relaxation puts the returned mass in the two cells next to the body, so a count that leaves them out sees the drift as smaller than it is and the correction as incomplete.
- NVIDIA GPU. On an A100 (NVHPC 25.11 and 25.5, OpenACC, with and without MPI, one rank) ib_mass_relax = 1 had no effect on the CI-sized mass budget: the mass change equals the run without it to every printed digit (+1.6e-3 in 100 steps at 8 cells per R, where a CPU run gives -4e-15), also with extrapolation boundaries and at 16 cells per R. With ib_state_wrt = T added to the same case the A100 gives -3.7e-15, the CPU value, so the failure is specific to the relaxation-only path (the one taken when no body moves and neither ib_state_wrt nor ib_heat_wrt is set). The case documentation of ib_mass_relax records 2e-13 on an A100 and an MI300A; that was not reproduced. The cause was not traced. Reproducer: ./mfc.sh run examples/2D_ibm_slip_cylinder/case.py -t pre_process simulation post_process -n 1 --gpu acc -- --mass_relax 1 compared with --mass_relax 0 (identical on an A100), then check_slip.py. The suite does not register the --mass_relax 1 case for this reason; IBM -> Fixed Circle -> Slip -> ib_mass_relax passes on the A100 with and without the option and does not discriminate.
- Curvature. The curvature term is exact for circles, spheres and the sides of cylinders; other shapes have none and keep the zero-gradient ghost pressure.
- Not re-measured here: the pressure of an accelerating slip cylinder (added mass), the uniform-flow pressure coefficient of a slip circle and the trajectory of a free slip cylinder behind a shock, which in the earlier study did not separate the options; and the comparison with the code before the curvature term, which cannot be made on master.
Reproduce
./mfc.sh run examples/2D_ibm_slip_cylinder/case.py -t pre_process simulation post_process -n 1 -- --steps 0 --cells_per_R 16 --half 8 --mass_relax 1
python3 examples/2D_ibm_slip_cylinder/check_slip.py examples/2D_ibm_slip_cylinder --case-args '--steps 0 --cells_per_R 16 --half 8 --mass_relax 1'
./mfc.sh run examples/2D_ibm_slip_cylinder/case.py -t pre_process simulation post_process -n 1 -- --mode vortex --mach 0.3 --cells_per_R 20 --ip_interp 2 --ccst
python3 examples/2D_ibm_slip_cylinder/check_slip.py examples/2D_ibm_slip_cylinder --case-args '--mode vortex --mach 0.3 --cells_per_R 20 --ip_interp 2 --ccst'
--mass_relax, --ip_interp, --ccst, --cells_per_R and --mach select the cases of the tables. The vortex mode compiles its own pre_process and simulation (the initial condition is an analytic patch). The suite runs the CI-sized mass budget (8 cells per R, a box of side 12 R, 100 steps, default ib_mass_relax) as 2D -> IBM -> Slip Cylinder -> Mass Budget.
Page last updated: 2026-11-23